TECHNICAL SPECIFICATIONS - COMPACT CYCLONE MULTIPHASE METER (CCM)

The CCM meter is an engineered product to the specific customer requirements. The following is a general description of the system specifications.

General

Inlet & Outlet Pipe dimension

2 – 6 inch Available

Materials

316L Stainless Steel Typical, Skid is Painted Black Iron

Wetted parts

316L Stainless Steel, Restricted to Instrument specifications

Pressure range

0 to 100 bar

Flowing Temperature range

0 to +100oC, Restricted to Instrument specifications

Instrument Temperature

0 to +55oC ambient, Optional Heaters Available

Installation

Skid mounted in horizontal or vertical pipe

Power suppl

120 VAC, 230 VAC 50/60 Hz or 24 VDC

Power consumption

TBD

Pressure drop

Typically 1 bar(14.5 psi)

Weight and size

Dependent of design flow rates.

Performance

Measuring Range

Water Cut

0 to 100%

GVF at operating conditions

0 to 100% GVF: Gas Void Fraction

Liquid and gas flow rates

The configuration of flow meters and instruments to be designed according to the actual flow rates and specifications.

Flow regimes

All, but for some special conditions, as severe slugging flow, contact manufacturer.

Individual flow meters

Gas flow meter

V-Cone, Annubar, Venturi, Orifice Plate

Liquid flow meter

Coriolis, Venturi, Turbine, PD Meter (Customer Specified Choice)

Water Cut Analyzer

Phase Dynamics Inc. Microwave Water Cut Analyzer

Typical overall uncertainties

Liquid flow rate

Relative error of +/- 5 %

Gas flow rate

Relative error of +/- 5 %

Water Cut

Absolute error of +/- 3 to 5 %, according to application

Signal Interfaces

Inputs

Analog

6 each 4-20mA Typical

Digital

ModBus, Field Bus, other Options Available

Outputs

Analog

4-20mA for Total Oil, Total Flow, Total Gas and Water Cut

Digital

ModBus, Field Bus, other Options Available

Approvals and Compliance

European standard Pending

Zone 1 and 2, EEx de IIC T6

Factory Mutual Pending
CSA Pending
(CSA Special Acceptance Received)

Class I, Div. 1, Groups,C,D

Class II,Div. 1, Groups E,F,G

Electromagnetic radiation

EMC pending

Environmental sealing

equivalent to NEMA 4

Installation and site requirements

 

Calibration fluids

Produced water known salinity

CalibrationNot required in the field,

Standard calibration procedures for single phase flow meters

Pneumatic air valve controls

Typical instrument air @ 7 barg (100psi)