CCM Technical Specifications
The CCM meter is an engineered product to the specific customer requirements. The following is a general description of the system specifications.
General
Inlet & Outlet Pipe dimension
2 6 inch Available
Materials
316L Stainless steel typical, skid is painted black iron
Wetted parts
316L Stainless steel, restricted to instrument specifications
Pressure range
0 to 100 bar
Flowing Temperature range
0 to +100oC Standard - other Temperatures available
Instrument Temperature
0 to +55oC ambient
Installation
Skid mounted in horizontal or vertical pipe
Power supply
120 VAC, 230 VAC 50/60 Hz or 24 VDC
Power consumption
Approximately 160 Watts
Pressure drop
Typically 1 bar (15 psi), depends on flow rates
Weight and size
Dependent on design flow rates
Performance
Measuring Range
Water Cut
0 to 100%
GVF at operating conditions
0 to 100% GVF: Gas Void Fraction
Liquid and gas flow rates
The configuration of flow meters and instruments to be designed according to the actual flow rates and specifications.
Flow regimes
All, but for some special conditions, as severe slugging flow, contact manufacturer.
Individual flow meters
Gas flow meter
Coriolis
Liquid flow meter
Water Cut Analyzer
Phase Dynamics Inc. Microwave Water Cut Analyzer
Typical overall uncertainties
Liquid flow rate
Relative uncertainty of +/- 5 %
Gas flow rate
Absolute uncertainty of +/- 3 to 5 %, depending on application
Signal Interfaces
Inputs
Digital
ModBus RTU
Outputs
Total Oil, Water & Gas, Water Cut, Pressure, Temperature, Level, Initiate Test, more
ModBus RTU, other options available
Approvals and Compliance
European Standard
Zone 1 and 2, EEx de IIC T6, GOST Standard
Factory Mutual & CSA
Class I, Div. 1, Groups,C,D Class II,Div. 1, Groups E,F,G
Electromagnetic radiation
EMC
Installation and site requirements
Calibration (not required in the field)
Standard calibration procedures for single phase flow meters
Pneumatic air valve controls
Typical instrument air @ 7 barg (100psi)