PHASE DYNAMICS MID RANGE MODEL NUMBERS
- ML AA B C D E FF GGG H "L" CONFIGURATION
- MU AA B C D E FF GGG H "U" CONFIGURATION
- MZ AA B C D E FF GGG H "Z" CONFIGURATION
Field AA designates process connection:
1R - ANSI Class 150 RF Flange 1J - RTJ 1F - Flat Face
3R - ANSI Class 300 RF Flange 3J - RTJ 3F - Flat Face
6R - ANSI Class 600 RF Flange 6J - RTJ 6F - Flat Face
9R - ANSI Class 900 RF Flange 9J - RTJ 9F - Flat Face
5R - ANSI Class 1500 RF Flange 5J - RTJ 5F - Flat Face
TH - National Pipe Threads
Field B designates measurement section diameter:
2 - 2 inch
3 - 3 inch
4 - 4 inch
Field C designates measurement section Material:
0 -Schedule 80 316L
1 -Schedule 80 Duplex 2205
2 -Schedule 80 Monel
3 -Schedule 80 Hastelloy
Field D designates measurement section Temperature Range
1 -160º F Maximum
2 -220º F Maximum
4 -400º F Maximum
6 -600º F Maximum
Field E designates measurement range:
0 -0 to Inversion Water in Oil
Field FF designates electronics enclosure type:
4X - NEMA 4X
EX - Explosion Proof
RM - Rack Mount
Field GGG designates system cable length:
020 - 20 feet (standard)
050 - 50 feet
100 -100 feet
150 -150 feet
Field H designates power requirements:
blank - 120 VAC 60 Hz (standard)
A - 230 VAC 50 Hz
B - 24 VDC
C - 120 VAC 50 Hz
Note: 1) Mid Range Analyzer, 0 to Inversion, is not available in 1-inch pipe.